PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (2024)

Contents hide

1PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat

2Important Safety Information

3Specifications

4Installation

4.1Replacing Existing Thermostat

4.2Installing Your New Thermostat

6Programming User Settings

6.1Default Thermostat Settings

6.2Setting Temperature Differentials

7Temperature Adjustment

8Additional Operation Features

9Battery Replacement

10Troubleshooting

11Wiring Diagrams

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (1)

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (2)

Important Safety Information

  • Always turn off power to the air conditioning or heating system prior to installing, removing, cleaning or servicing the thermostat.
  • This thermostat is a dual-power thermostat and either requires 24 Volts AC Power or two (2) properly installed “AA” alkaline batteries for normal operation and control of the heating or cooling system. Refer to “Low Battery Detection and Replacement” section for more information.
  • This thermostat should only be used as described in this manual. Any other use is not recommended and will void the warranty.

Specifications

  • Electrical Rating: 24 Volt AC (18-30 Volt AC)
    • 1 amp maximum load per terminal
    • 2 amp total maximum load (all terminals) (Model PSTS11NP)
    • 3 amp total maximum load (all terminals) (Model PSTS21NP)
  • Control Range: 45° – 90° F (7°- 32° C)
  • Accuracy: +/- 1° F (+/- .5° C)
  • AC Power: 18-30 Volt AC
  • DC Power: 3.0 Volt DC (2 AA Alkaline batteries included)
  • Model PSTS11NP: Compatibility with low voltage single-stage gas, oil or electric heating or cooling systems, including single-stage heat pumps, can also be used on 250mv to 750mv millivolt heating-only systems.
  • Model PSTS21NP: Compatibility with low voltage multi-stage gas, oil or electric heating or cooling systems, including multi-stage heat pumps.
  • Terminations, Model PSTS11NP: Rc, Rh, B, O, Y, W, G, C
  • Terminations, Model PSTS21NP: R, O, B, C, Y1, E/W1, G, W2

Installation

Replacing Existing Thermostat

  1. Always turn off power to the air conditioning or heating system prior to removing the existing thermostat.
  2. Remove the cover of your old thermostat and locate the wire terminals.
    Do not remove wires from terminals yet.
  3. Using small pieces of masking tape, label wires prior to removal from terminals. Use the chart below to determine the new terminal designations for your new thermostat.
    Old Terminal from Existing ThermostatNew Terminal for New Thermostat (PSTS11NP)New Terminal for New Thermostat (PSTS21NP)Terminal Description
    V or RcRcCooling Transformer
    M, 4, Rh, or RRhHeating Transformer
    R, V-VR or VR-RR24 VAC
    BBBReversing Valve (Heating)
    OOOReversing Valve (Cooling)
    Y, Y1 or MYY1Cooling or Compressor for HP System
    E, H, W, or 4WE/W11st Stage Heat

    or Emergency Heat

    G or FGGFan Control
    C, X or BCC24 VAC Common
  4. After labeling and removing all wires from terminals, unscrew the existing thermostat sub-base from wall. Secure wires to prevent them from slipping into the hole in the wall.

NOTE–MODEL PSTS11NP: This thermostat is designed for use with 24 Volt-AC low voltage single-stage gas, oil or electric heating or cooling systems, including single stage heat pumps and can also be used on 250mv to 750mv millivolt heating-only systems. Do not use this thermostat on applications with voltages above 30 Volts AC.

NOTE–MODEL PSTS21NP: This thermostat is designed for use with 24 Volt-AC low voltage multi-stage gas, oil or electric heating or cooling systems, including multi-stage heat pump systems. Do not use this thermostat on applications with voltages above 30 Volts AC.

Installing Your New Thermostat

NOTE: If installing this thermostat in a new installation, locate the thermostat 4 to 5 feet above the floor in accordance with applicable building codes. Install the thermostat in a location that provides good airflow characteristics and avoid areas behind doors, near corners, air vents, direct sunlight or heat generating devices. Installation in these areas could impact thermostat performance. Wiring must conform to all building codes and ordinances as required by local and national code authorities having jurisdiction.

  1. Turn off power to the air conditioning or heating system prior to installing a thermostat.
  2. Place the system switch on the front of thermostat to the OFF position.
  3. Place fan control switch on front of the thermostat to AUTO position.
  4. Remove front of the thermostat body from sub-base by pressing release latch.
  5. Place the thermostat sub-base against wall in the desired thermostat location.
  6. Guide thermostat wires through hole in sub-base. Continue to hold against wall.
  7. Mark placement of mounting holes as appropriate and drill using 3/16″ drill bit.
  8. Gently tap supplied plastic anchors into the holes in the wall.
  9. Place the thermostat sub-base against the wall in the desired location, making sure the mounting holes are aligned and the thermostat wires are inserted into the opening in sub-base.
  10. Fasten sub-base to wall using supplied screws.
  11. Connect wires to quick wiring terminal block using the new terminal designations. See section 9.
  12. Make sure all of the wire connections are secure and not touching any other terminal to prevent electrical shorts and potential damage to the thermostat.
  13. Turn the front thermostat body over, exposing the rear view of the circuit board.
  14. Locate the internal °F /° C switch on the circuit board. Using your fingers, flip the switch toward the preferred temperature °F / °C scale.
  15. Locate the internal fan option switch, HG (Gas) / HE (Elec) on the circuit board. This switch controls the heating system fan delay. Select gas for gas or oil fired systems. This will allow the furnace to run for a few seconds before initiating the fan. Select electric for systems with electric furnace elements that require the fan to come on immediately. Using your fingers, flip the switch toward HG (Gas) or HE (Elec).
    NOTE: For heat pump systems, the fan option switch should be set according to the second stage heating system type.
  16. Locate the internal NORM / HP switch on the circuit board. This switch configures the thermostat for conventional (NORM) heating and cooling systems or heat pump (HP) systems. Using your fingers, gently flip the switch toward NORM or HP.
  17. Attach front body of thermostat to the sub-base of thethermostat, being careful to align the terminal pins on the front body with the terminal block onthe sub-base.
  18. Open front thermostat door and open battery compartment door.
  19. Install two new “AA” alkaline batteries. Locate the positive (+) ends of the batteries and match them with the positive (+) terminals located in the battery compartment. Close battery compartment.
  20. Restore system power so you can test installation.PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (3)

NOTE: If the thermostat was powered (batteries installed) prior to accomplishing steps 14 through 16, you will need to reset the thermostat to register thermostat switch configurations prior to programming any user settings. Gently press the RESET button on the front of the thermostat using a paper clipor a small pencil tip.
NOTE – MODEL PSTS21NP: If the thermostat is configured for a conventional system and the system switch is in the EMER position, the unit will still function in a conventional 2-stage HEAT mode, but the display will flash NO AUX SET.

Testing Your New Thermostat

WARNING! Read BEFORE Testing

  • Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation. This could damage the thermostat and void the warranty.
  • Do not select COOL mode if the outside temperature is below 50° F (10° C).
    This could damage the controlled cooling system and cause personal injury.
  • This thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling. This thermostat automatically provides a 5-minute delay after turning off the cooling or heating system output to protect the compressor.

NOTE: Test your thermostat prior to programming any user settings. Pressing the RESET button will erase any user entries previously programmed and return them to their default values.

  1. Place the system switch in the HEAT position.
  2. Press the button on the keypad until the set point temperature setting is a minimum of 3 degrees higher than the current room temperature. The heating system should start within several seconds. The fan may not turn on immediately due to the heating system built-in fan delay.
  3. Place the system switch in the OFF position. The heating system should stop within several seconds with conventional heating or cooling systems. On heat pump systems you must wait 5 minutes for the automatic compressor short cycle protection period to expire, or press the RESET button to bypass this feature for initial testing purposes. Pressing the RESET button will erase any user program settings.
  4. place the system switch in the COOL position.
  5. Press the button on the keypad until the set point temperature is a minimum of 3 degrees lower than the current room temperature.
  6. The cooling system should start within several seconds. Place the system switch in the OFF position. The cooling system should stop within a few seconds.
  7. Place the fan switch in the ON position. The system blower should start.
  8. Place the fan switch in the AUTO position. The system blower should stop.

Programming User Settings

Default Thermostat Settings

FunctionStatus After Reset
Operation ModeNormal Operating Mode
Room Temperature70˚ F (21.0˚ C), to be renewed within 5 seconds
Set Point TemperatureAccording to system switch Heat or Off: 62˚ F (17.0˚ C)

Emergency Heat (PSTS21NP only): 62˚ F (17.0˚ C)

Cool: 85˚ F (29.0˚ C)

Temperature Scale˚F or ˚C dependent on switch setting
Low Battery WarningOff, to be renewed within 5 seconds. Off if 24V is present
1st Stage Differential0.5˚ F (0.25˚C)
2nd Stage Differential2˚ F (1.0˚ C)
Short Cycle Protection TimerReset
Output RelaysOff

Setting Temperature Differentials

The default settings for the first and second-stage differentials are compatible with most systems and applications. This is normally set at time of installation and usually does not require any modification under normal operating conditions. If you feel that your system is turning on too often, simply follow the instructions below.
NOTE: The first and second-stage differential settings are the same for both the heating and cooling systems.
Setting First Stage Differential
The default setting is 0.5° F (0.25° C). The room temperature must change .5° F
(0.25° C) from the set point temperature before the thermostat will initiate the system
in heating or cooling.

  1. In normal operating mode, press and hold the and buttons at the same time for 3 seconds. LCD display will show “SET D1 x°”, where “x” equals the °F / °C differential setting. This is the current first stage differential setting.
  2. Press the or buttons to set the first stage differential to your desired setting of .5°, 1°, or 2° F (.2, .5° or 1.0° C).

NOTE–MODEL PSTS11NP: Once you have finished setting the first stage differential, you can wait 5 seconds and the thermostat will return to the normal operating mode. Or you can press both the and buttons at the same time to return to normal operating mode.
NOTE–MODEL PSTS21NP: If you do not wish to change the second stage differential, you can wait 5 seconds and the thermostat will automatically return to the normal operating mode. Otherwise, you can press both the and buttons at the same time to return to normal operating mode.

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (4)Setting Second Stage Differential

The default setting is 2° F (1.0° C). The room temperature must change 2° F (1.0° C) in addition to the first stage differential setting before the thermostat will initiate the second stage of the system in heating.

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (5)

  1. Press and hold the and buttons at the same time againand the LCD display will show “SET D2 x°”, where “x” equals the °F / °C differential setting. This is the current second stage differential setting.
  2. Press the or buttons to set the second stage differential to your desired setting of 2°, 3°, 4°, 5° or 6° F (1°, 1.5°, 2°, 2.5° or 3° C).

NOTE – MODEL PSTS21NP: Once you have finished setting the second stage differential, you can wait 5 seconds and the thermostat will return to the normal operating mode. Or you can press both the and buttons at the same time to return to normal operating mode.
NOTE: To erase all user program settings, gently press the RESET button using a paper clip or a small pencil tip. This will return all thermostat settings to their default values, erasing all program settings entered by the user.

Temperature Adjustment

NOTE: This thermostat has separate heating and cooling set points, which can be reviewed or changed by selecting either HEAT or COOL with the system switch.

Review Set TemperaturePROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (6)

  1. Press and hold the or button. The current set point temperature will be displayed in place of the current room temperature, and the indicator SET will be displayed.
  2. The display will return to normal operating mode when the or buttons are released. The SET indicator will turn off, indicating that the current temperature shown in the display is room temperature.

Changing Set TemperaturePROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (7)

  1. Press and hold the or button for more than 1 second.
    The entire display will flash once and the SET indicator will be flashing. Release the or button and press the or button again to adjust the set temperature.
  2. The display will return to normal operating mode after 5 seconds, or you can press both the and buttons at the same time to return to normal operating mode.
  3. The SET indicator will turn off in the display, indicating that the current temperature shown in the display is room temperature.PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (8)

Additional Operation Features

Compressor Protection Feature

This thermostat includes an automatic compressor protection feature to avoid potential damage to the system from short cycling. This thermostat automatically provides a 5-minute delay after turning off the cooling system output to protect the compressor. This protection is also present in the heat mode of operation on heat pump systems to protect the compressor.
NOTE: The installer can bypass the compressor protection feature by pressing the RESET button. This will erase all user program settings, returning all settings to their default values. This should only be used during installation for testing purposes or to reset a thermostat to regain normal operation.

Low Battery Detection and Replacement

This dual-power thermostat requires two (2) new, properly installed “AA” Alkaline batteries to provide proper thermostat power when 24 volt AC power fails or is not connected to the thermostat. When the batteries start to become too weak to provide proper operation, the thermostat will begin to display a 3 stage low battery indicator.PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (9)

Low Battery StageBattery IndicatorDurationAction
Stage 1Solid0-30 DaysReplace Batteries as Soon as Possible.
Stage 2Flashes Every 2 Seconds31-60 DaysReplace Batteries Immediately to Provide Proper Operation.
Stage 3Flashes Every 1 Second61-90 DaysReplace Batteries Urgently to Provide Proper Operation.

The 3 stage low battery indicator is provided to inform the user when the batteries require immediate attention. We recommend replacing the batteries as soon as the low battery indicator appears. If the batteries are not replaced after the low battery indicator first appears, the thermostat may not provide proper heating or cooling system operation. Even if the low battery indicator does not appear, the batteries should be replaced at least once a year, or if you plan on leaving the premises for over a month. This dual-power thermostat can be powered from 24 volts AC or battery power. To determine if 24 volt AC power is connected to the thermostat, refer to the installation and wiring diagram section. If you cannot determine how this thermostat is powered, call a professional service technician to determine the type of installation and the proper operation of your system.

Non-Volatile Memory

In the event of a power failure, the Non-Volatile Memory feature allows all settings to be recovered, eliminating the need to reset the temperature and differential settings. When AC power is restored after an outage or batteries are reinserted, all settings are retrieved from memory and reinstated.

Status IndicatorsPROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (10)

  • HEAT: This will turn on whenever the system switch is in HEAT mode. “HEAT” will flash when the heating system is running.
  • COOL: This will turn on whenever the system switch is in cool mode. “COOL” will flash when the cooling system is running.PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (11)
  • AUX (PSTS21NP ONLY): This will turn on when the auxiliary (second stage) of heating is active. The auxiliary stage of heating is usually the least economical stage of heat and typically runs when the first stage of heat cannot keep up with the temperature demand.
    NOTE: AUX is also displayed when the system switch is in the Emergency (EMER) Mode.

Battery Replacement

Replacing the Batteries

  1. Open front cover and locate the battery compartment door.
  2. Gently remove the two “AA” alkaline batteries located in the battery compartment.
  3. Install two new “AA” alkaline batteries into battery compartment. Make sure to match the positive (+) ends of the batteries with the positive (+) terminals located in the battery compartment.
  4. Close battery compartment. The low battery indicator should not appear in the display.

Troubleshooting

  • Symptom: Thermostat does not turn on heating or cooling system.
    Potential Solution: Check to see if OFF is shown in display. This indicates that the system is turned off at the thermostat. Move system selector switch to HEAT or COOL position. After the compressor short cycle protection 5-minute period expires, the system should start. Compressor protection features may be in effect due to compressor short cycle conditions. See Section 6. Heating or cooling system may be malfunctioning. Call a professional service technician immediately to verify system operation.
  • Symptom: Thermostat turns on heating instead of cooling, or cooling instead of heating.
    Potential Solution: Check thermostat wiring to make sure the heating and cooling stages are connected to the correct terminals on the wiring block. See Section 9.
  • Symptom: Thermostat turns heating or cooling system on too often or not often enough.
    Potential Solution: Increase or decrease temperature differential settings as appropriate
    to provide the desired performance level. See Section 4.
  • Symptom: Low battery indicator is blinking in thermostat display.
    Potential Solution: Replace batteries immediately to maintain proper system operation. See Section 7.
  • Symptom: OFF is shown in thermostat display and heating or cooling system will not start.
    Potential Solution: This indicates that the system is turned off at the thermostat. The thermostat must be in HEAT or COOL mode of operation to control the heating or cooling system. Move the system selector switch to the HEAT or COOL position.
  • Symptom: Thermostat display is blank.
    Potential Solution: It is possible that AC power is not present at the thermostat, and/or the batteries are drained. Check fuse, circuit breaker and thermostat wiring as appropriate to verify AC power is available. Replace batteries before reprogramming thermostat. See Section 7. If AC power is present, call a professional service technician to verify thermostat and system performance.
  • Symptom: HI is shown in the thermostat display.
    Potential Solution: The temperature sensed by the thermostat is higher than the 99° F (37° C) upper limit of the thermostat’s display range. The display will return to normal after the sensed temperature lowers within the 40° to 99° F (4° to 37° C) display range. Turn on the cooling system or use other methods to lower the temperature accordingly. This condition could occur from the system being turned off during an exceptionally warm period or upon installation when the thermostat has been stored for a long period of time in a warm vehicle or location prior to being installed.
  • Symptom: NO AUX SET is shown in the thermostat display.
    (PSTS21NP only)
    Potential Solution: The thermostat (PSTS21NP only) is configured for a conventional system, and the system switch is in the EM HEAT position. The unit will still function in a conventional 2 stage HEAT mode, but the display will flash NO AUX SET. Move the system switch to the HEAT position.
    Symptom: LO is shown in the thermostat display.
    Potential Solution: The temperature sensed by the thermostat is lower than the 40° F (4° C) lower limit of the thermostat’s display range. The display will return to normal after the sensed temperature rises within the 40° to 99° F (4° to 37° C) display range. Turn on the heating system to raise the temperature as needed for comfort within the room. This condition could occur from the system being turned off during a cold weather period or upon installation when the thermostat has been stored for a long period of time in a cold vehicle or location prior to being installed. The thermostat should be allowed to warm up prior to installation to allow proper heating control once installed.
  • Symptom: Cannot program a set point temperature higher than 90° F (32° C).
    Potential Solution: This is above the normal thermostat temperature setting range of 45° to 90° F (7° to 32° C).
  • Symptom: Fan continues to run whether the system is on or off.
    Potential Solution: Check that the fan control switch is in the AUTO position. This will allow the fan to run only when the heating or cooling system is turned on and running.
    Check thermostat wiring to make sure that the fan control wiring is connected to the correct terminals on the wiring block. See Section 9.
  • Symptom: The room is too warm or too cold.
    Potential Solution: See Section 5. Review current set point and change as necessary.
  • Symptom: HEAT or COOL is flashing, but the system is not running.
    Potential Solution: The thermostat is telling the heating or cooling system to run, but the system is not responding. You may need to call your local heating and air conditioning contractor.

Wiring Diagrams

PSTS11NP: Single Stage Conventional Systems (Single Transformer)PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (12)

NOTES: 1. Transformer commonly not required for the battery-only operation of the thermostat. 2. For the heating or cooling-only system, ignore the opposite connection. 3. For 2-wire 24 Volt AC or 250 mV – 750 mV millivolt heating systems, ignore cooling connection and fan control.

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (13)

PSTS11NP: Single-Stage Heat Pump SystemPROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (14)

NOTES:

  1. Transformer commonly not required for the battery-only operation of the thermostat.
  2. For units requiring reversing valve to be energized during heating, connect reversing valve to the B terminal. For units requiring reversing valve to be energized during cooling, connect reversing valve to O terminal.

PSTS21NP: Conventional Systems (Single Transformer)

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (15)

NOTE: Transformer common not required for the battery-only operation of thermostat

PSTS21NP: Multi-Stage Heat Pump SystemsPROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (16)

NOTES:

  1. Transformer is commonly not required for the battery-only operation of the thermostat.
  2. The jumper is required to use Auxiliary Heat for both Second Stage and Emergency Heat on units without separate e Emergency Heat and Auxiliary Heat terminals.
  3. For units requiring reversing valve to be energized during heating, connect reversing valve to the B terminal. For units requiring reversing valve to be energized during cooling, connect reversing valve to the O terminal.

File: PSTSNP-100-001.ai
NOTE: If changes are required to this file, please notify Braeburn Systems BEFORE making them.
Size: 26.25”W x 8”H, folds to 3-3/4”W x 4”H (666.75mm x 203.2mm, folds to 95.25mm x 101.6mm)
Please make sure the warranty page is on the back when folded.
Ink: 1 color, Black, 2 sides. Front and back bleeds
Stock: Use existing weight and color (white).
NOTE: Blue keylines do not print.

Reference

Download Manual

PROSELECT PSTS11NP Builder Series 1H-1C Non-programmable Thermostat Installation Manual

Other manuals

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Product Specification Guide

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (17)

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual

PROSELECT PSTS11NP Builder Series 1H/1C Non-programmable Thermostat Installation Manual - thermostat.guide (2024)

References

Top Articles
Latest Posts
Article information

Author: Horacio Brakus JD

Last Updated:

Views: 6029

Rating: 4 / 5 (71 voted)

Reviews: 94% of readers found this page helpful

Author information

Name: Horacio Brakus JD

Birthday: 1999-08-21

Address: Apt. 524 43384 Minnie Prairie, South Edda, MA 62804

Phone: +5931039998219

Job: Sales Strategist

Hobby: Sculling, Kitesurfing, Orienteering, Painting, Computer programming, Creative writing, Scuba diving

Introduction: My name is Horacio Brakus JD, I am a lively, splendid, jolly, vivacious, vast, cheerful, agreeable person who loves writing and wants to share my knowledge and understanding with you.